Mixed Convection from a Rough Plate

Its been a long time since my last blog entry; there are new developments.

After completing the vertical convection measurements, I returned the Convection Machine to its horizontal orientation and did some runs to make sure everything was as before.  But things were not the same.

With the rough side facing down, the transition where mixed convection dropped below the linear asymptote had disappeared.  Varying parameters did not restore the dip.  Changing inclination of the plate; tilting the wind-tunnel; resealing the cardboard around the fan; nothing I tried restored the dip.  Something has permanently changed in the wind-tunnel or the plate.

So I reran the measurements of horizontal upward and downward facing mixed convection.  The new curves match simple L2 and L4 norms of the forced and natural convection components.  My guess of what changed has to do with the suspension of the plate.  The vertical suspension was a single long wire which, after hooking around the a top corner post, wrapped across the back and hooked around the other top corner post.  Wrapping around the back compressed the back sheet and insulation against the back side of the rough plate.  Perhaps the pressure closed gaps in the glue between aluminum and insulation.

Having data for horizontal forced flow with 3 plate orientations, it was time to measure downward forced flow with a vertical plate. Because vibration of the plate had caused excess convection with the single wire suspension, I added two wrap-around wires pulling in opposite directions to the plate suspension.  This new suspension is quite rigid and works with the wind-tunnel in any orientation.

I added four legs to support the wind-tunnel upright with the fan drawing downward.  I was expecting either L2-norm mixing or for convection to drop below the natural level when the natural and forced components were equal.  But it was neither!  I devised a model which transitions between L2 and L4 norm that matched the measurements well; it is detailed in my paper.

Because the opposed mixing was unexpected, aided mixing had to be tried.  It also turned out to involve a transition between L2 and L4 norms, but with a gentler transition.

I have finished writing the article and put it and the supplementary data on http://people.csail.mit.edu/jaffer/convect

As described in the paper, the next step is to shave 4.mm off the rough side of the plate and repeat the measurements.

Monday, June 13, 2016

Mixed Convection from a Vertical Rough Surface

I turned the wind-tunnel on its side and hung the plate vertically as shown in the photograph.



These graphs show that my mixed convection model is successful from natural through forced convection for horizontal and vertical rough plates with forced flow perpendicular to the natural flow.  The leftmost red dot in each graph is the natural convection (Re=0) for that orientation; it is placed at Re=1000 so that it can appear on the graph.


The L4-norm for downward convection indicates that the interaction between the downward mode and forced convection is more competitive than the fairly cooperative L2-norm of the vertical and upward modes.

Horizontal downward and vertical natural convection from the rough plate match that expected from a smooth plate.  Horizontal upward convection matches assuming that the upper (rough) surface convection is reduced by 93% of the non-forced convection from the four adjoining sides.  In order to test if horizontal upward convection is the same for rough and smooth, I will cover the rough surface with a flat sheet of aluminum and repeat the test.

I have started writing a paper titled "Mixed Convection from a Rough Plate".  Which journal should I submit it to?

Wednesday, January 27, 2016

Forced Convection on Convection Machine 2.0

The new back eliminated the dual modes seen earlier with peak ΔT=15K. Reducing the r/min to m/s conversion by 2% (which is within the ± 3% error band of the anemometer) and adjusting the breakpoint results in a beautiful fit!

The points at Re=3545 and Re=5231 could be following either the Smooth Turbulent Asymptote or the Transition Model; it's too close to tell. The reason that the Transition Model has less convection than the Smooth Turbulent Asymptote below Re=6000 is because the leading edge of the boundary layer is modeled as thinner than the roughness; but division by the local characteristic length, 0, is undefined at the leading edge.

Friday, January 8, 2016

Slightly Tilted Downward Convection

With the current configuration, I am measuring the natural convection from a plate inclined a few degrees from facing downward. Turning the front tuning pegs shortens the support wires and tilts the plate.

This graph shows that downward convection does not blend with other convective modes. With θ between 87° and 90° downward convection is in control; between 0° and 87° the vertical mode is dominant. I have modified the UCT3 formula in the Downward Natural Convection section with this new knowledge.
R = min(LH, LW)/2
h = k⋅max(Nu9.3(Ra(LH) cos θ)/LH , Nu45(Ra(R) sin θ)/R) 0°≤θ≤+90° UCT3
The random variation in the plot above makes it less convincing than it might be. I modified the firmware to increase the heating threshold from 5 K to 15 K, which increases the average ΔT from 3.7 K to 11 K and reduces the relative variation by about a factor of 3.


Running the tilt tests at the higher temperature difference results in markedly reduced variation as can be seen by the proximity of the half-interval measurements (black dots) to the full-interval measurements (red dots). But the slope below 87.5° clearly does not match that derived from Nu9.3, the natrual convection from a smooth vertical plate!  More about this below.
I also ran a series of forced convection trials with the 15 K peak temperature difference:

There are several things to notice about this graph. The tests where only part of the plate had roughness penetrating the boundary layer seemed to have two distinct breakpoints: Re=16666 and Re=22222. For nearly all the measurements, the half-interval measurements (black dots) are very close to the full-interval measurements (red dots). There are two which are not so close. The black dots around Re=7440 lie close to the line, indicating the wind speed change which occured partway through the run. This can be seen in the bottom panel on page 8 of the PDF. The dots at Re=8237 had the same windspeed, perhaps indicating that the system spent time in both breakpoint modes.
Below Re=7500 the measurements track a slope of turbulent convection (Re4/5). Unfortunately the wind-tunnel can't produce wind speeds below 0.25 m/s (Re=4900), so we can't see the transition to natural downward convection.

Returning to natural convection, either the natural convection from a rough vertical surface differs from that of a smooth vertical surface or the formula combining the downward and vertical convection is wrong. The former can be tested by suspending the plate vertically. I plan to do this by wrapping the wire suspending the plate around its (insulated) back. In order to protect the insulation from being cut by the wire, a sheet of aluminum should be glued to the back. I was planning to do this already in order to test upward natural convection.


Here is the back side of the plate ready to have the 0.65 mm sheet of aluminum glued to it. Notches have been cut (using the "nibbler" on the sheet) near the sheet corners to catch the wires which will suspend it.



Gluing completed.
 

Here the rough surface of the plate is facing up in the wind tunnel. But first I must rerun all the downward facing measurements.


Saturday, November 21, 2015

Forced Convection From a Rough Plate

In October I collected data from experiments over the full range of wind speeds possible in my wind tunnel: 0.45m/s to 4.5m/s.  More time was consumed in making a simulation which matched the dozen datasets.  In this speed range all convection is a blend of natural and forced convection.  I built the simulation to support variable L-norms for combining the natural and forced convection components.  The L-norm that allowed match to the data was L4, which was also the only working L-norm for combining the three speed ranges of forced convection.  The L4-norm looks like: (N4+F4)1/4.  The main goal was to test my correlation for forced convection from a rough plate:
This graph shows the experimental support for my "Scaled Colburn Analogy Asymptote" formula for forced convection from a rough plate.  Here is a link to a pdf of graphs comparing simulation with experiment.

The largest uncertainty in the measurements is the wind-speed (proportional to  Re), which the anemometer gives as 3% at 4m/s.  As the speed reduces, the uncertainty grows quickly.  The "fan law" says that wind-speed is proportional to fan rotation rate.  This turned out to not hold at speeds above 3m/s, which had a lesser slope than at low speeds.  At high speeds, the anemometer readings inside the wind-tunnel are erratic.  This link to the fan wind-speed curve shows the formula used in simulations versus 5 measured wind-speed data runs.


Some of my assumptions were wrong.  Natural convection from a rough surface turns out to be greater than convection from a smooth surface both upward and downward facing.  In order to obtain the matches (red versus blue, green) shown below, the downward convection is multiplied by 2.44; the upward convection by 1.56.  The rough plate surface has an area 2.44 times that of a smooth surface and 1.56 is its square-root.  There is latitude in these numbers and convection from the four sides; experiments with the rough surface covered by a sheet of aluminum would refine the model.


 The blue trace is the measured temperature from the smooth back.  The simulated red trace is a good match when the back is on top.   The poor match below when the smooth back is facing down is probably because the plate was not suspended, but sitting on small wooden blocks without much clearance.  I will perform the measurement again with more clearance in the future.